ASTM D4417 METHOD C PDF

Historical Version s - view previous versions of standard. Work Item s - proposed revisions of this standard. More D For this reason, surface profile should be measured prior to coating application to ensure conformance of a prepared surface to profile requirements specified by the manufacturer of a protective coating or the coating job specification. The instruments described are readily portable and sufficiently sturdy for use in the field.

Author:JoJoktilar Meztinos
Country:Denmark
Language:English (Spanish)
Genre:Travel
Published (Last):13 September 2009
Pages:455
PDF File Size:1.39 Mb
ePub File Size:6.33 Mb
ISBN:529-3-57919-697-8
Downloads:46952
Price:Free* [*Free Regsitration Required]
Uploader:Mojind



Authored by Alana Fossa. For hot-dip galvanizing applications, it is possible to measure and verify the steel surface profile according to ASTM D, Standard Test Methods for Field Measurement of Surface Profile of Blast Cleaned Steel, prior to application of repair materials where the surface has been prepared via power tool or abrasive blast cleaning methods. Recent changes to ASTM D provide updated test methods to reflect the latest advances in technology and newly accepted industry research.

The three test methods described within D for measuring surface profile include visual comparators, surface profile depth micrometers, and replica tape.

Only the use of surface profile depth micrometers and replica tape were updated, and the specification changes are as follows:. Larger repair areas or prepared hot-dip galvanized surfaces for painting can be measured with 10 readings taken from a minimum of three, 6x6 inch 15x15 cm areas.

The standard does not address discarding outliers, but an update to the standard addressing outlier readings is planned. These changes reflect industry research on current tooling which revealed averaged measurements are consistently less than the values obtained using replica tape.

Instead, recording of the highest reading when using a depth micrometer most closely matches the same measurements produced using replica tape.

As a result, only two readings per area are now required to be averaged to obtain one measurement, instead of the three readings previously required. For measurements that fall between tape sizes, it is still required that two readings using each tape are to be averaged to comprise one reading i.

Larger repair areas or prepared hot-dip galvanized surfaces for painting can be measured with two readings taken from a minimum of three, 6x6 inch 15x15 cm areas.

For more information related to surface preparation as it relates to hot-dip galvanized steel, you can contact AGA Corrosion Engineer Alana Hochstein at ahochstein galvanizeit. The material provided herein has been developed to provide accurate and authoritative information about after-fabrication hot-dip galvanized steel. This material provides general information only and is not intended as a substitute for competent professional examination and verification as to suitability and applicability.

The information provided herein is not intended as a representation or warranty on the part of the AGA. Anyone making use of this information assumes all liability arising from such use. Was this answer helpful? Are you still looking for the right answer?

Ask an Expert. Post Comment. Login Close. October 18, Authored by Alana Fossa. Leave this field blank.

QUEEN OF CAMELOT NANCY MCKENZIE PDF

Differences in Surface Profile Measurements: ASTM D4417- Method B vs. Method C

Authored by Alana Fossa. For hot-dip galvanizing applications, it is possible to measure and verify the steel surface profile according to ASTM D, Standard Test Methods for Field Measurement of Surface Profile of Blast Cleaned Steel, prior to application of repair materials where the surface has been prepared via power tool or abrasive blast cleaning methods. Recent changes to ASTM D provide updated test methods to reflect the latest advances in technology and newly accepted industry research. The three test methods described within D for measuring surface profile include visual comparators, surface profile depth micrometers, and replica tape. Only the use of surface profile depth micrometers and replica tape were updated, and the specification changes are as follows:. Larger repair areas or prepared hot-dip galvanized surfaces for painting can be measured with 10 readings taken from a minimum of three, 6x6 inch 15x15 cm areas. The standard does not address discarding outliers, but an update to the standard addressing outlier readings is planned.

DVR4400 MANUAL PDF

ASTM D4417

ASTM D ASTM B ASTM F ASTM E ASTM A ASTM D A number in parentheses indicates the year of last reapproval.

ELIZA ORZESZKOWA ABC PDF

Surface Profile - A Comparison of Measurement Methods

Three types of devices are available to take measurements of this surface profile: replica tape, depth micrometers fitted with pointed probes, and stylus roughness testers. This paper presents results from a recent analysis of measurements taken by the three device types on steel blasted with an assortment of blast media and proposes a new method of depth micrometer measurement called average of the maximum peaks. Steel surfaces are frequently cleaned by abrasive impact prior to the application of protective coatings. This process removes previous coatings and roughens the surface to improve coating adhesion.

DIARY OF A LOST GIRL KOLA BOOF PDF

.